Motor
Run Capacitor -
Continuous Operation : |
  
|
| Safety
Class : |


| The combination of Capacitance value and Voltage or should there be a Dimensional constraint, please contact us for a design suited to your particular needs. |
|
|
|
| Reference standard : |
-
EN60252-1994, VDE0560-8, IEC.252-1993
UL810, CSA C 22.2
- JIS : 4908-1995
|
| Safety Approval : |
|
|
| Electrical Characteristic : |
- Capacitance range : 2.5
- 100£gF
- Rated Voltage : 125VAC, 220VAC, 250VAC, 370VAC, 400VAC, 450VAC, 500VAC, 600VAC, 630VAC, 800VAC
-
Capacitance Tolerance : ¡Ó5%; ¡Ó10%
-
Dissipation factor (DF) ¡Ø 0.002 at 23¢J 50/60Hz
-
I.R. : Terminal - Terminal ¡Ù5000£[£gF
Terminal - Case ¡Ù1000M£[£gF
-
Min. / Max. Operate Temperature : -25~70¢J / -40~85¢J
-
Rated frequency : 50 - 60Hz
-
Testing Voltage : Terminal - Terminal : 2.15 x Un 10sec (can be customer design)
Terminal - Case : 3000AC 10sec
-
Maximum Permissible Overvoltage : 110% of rated voltage
-
Maximum Permissible Overcurrent : 130% of rated voltage
-
Maximum Permissible Reactive output (Voltage-Ampere) : 135% of rated Volt-Ampere
-
Pulse Voltage rise & fall time dV/dt : detail information available on require
-
Polypropylene film dielectric
|
| Life Expectancy : |
| Class A |
Class B |
Class C |
Class D |
| 30,000hrs |
10,000hrs |
3,000hrs |
1000hrs |
|
| Some of the standard
capacitor configuration. |
 |
 |
|
|